First, rule out the simple things
- Thermostat: set to heat, a few degrees above room temperature, and the fan set to auto, not on. With the fan on, air blows between heating cycles and feels cool.
- Batteries: replace them if the screen is faint or blank.
- Filter: a clogged filter makes the furnace overheat and shut the burners off.
- Power: the furnace switch, which looks like a light switch near the furnace, must be on, and the breaker not tripped.
- Panel door: the furnace will not run unless the blower door is closed firmly on its safety switch.
Check the vent pipes outside
High-efficiency furnaces take in air and send out exhaust through two plastic pipes, usually on a side wall or the roof. Snow drifts, ice or a bird’s nest can block them, and the furnace then shuts down. After a storm, clear snow from around the pipes without pushing anything inside. This is especially common in Monument and other snowy spots on the Palmer Divide.
Read the blinking light
Most modern furnaces have a small window in the lower panel with a light that flashes a code. Count the flashes and look up the code on the label inside the door. Common codes point to the pressure switch, the flame sensor, the limit switch or an ignition failure. Write it down for the technician.
What the common faults mean
- Igniter: the part that glows to light the gas. If it cracks, the burner never lights.
- Flame sensor: a thin metal rod that proves the flame is lit. When it is coated, the furnace lights and then shuts off after a few seconds.
- Pressure switch: confirms the exhaust is venting. A blocked vent, a frozen condensate drain or a failing inducer motor trips it.
- Limit switch: shuts the burners off when the furnace overheats, usually because of poor airflow.
- Gas supply: other gas appliances not working, or a propane tank running low, points to the supply.
Altitude matters
Gas furnaces in the Colorado Springs area are adjusted for the thin air at more than 6,000 feet. A furnace that was not set up for altitude can run poorly, build up soot or trip its safety switches more often. If your furnace was recently installed and keeps shutting off, mention it when you call.
When not to try anything
If you smell gas, hear the carbon monoxide alarm, see scorch marks on the furnace or hear loud bangs when it lights, do not reset it or keep trying. Leave the house and call 911 or your gas utility from outside. Do not remove burner covers or bypass safety switches.
When to call
Call when the simple checks do not help, when the same code keeps returning, when the furnace lights and shuts off repeatedly, or when water is pooling around it. Tell the technician the brand and model, the code and what you have checked. More on heating faults is on the furnace repair page.
Common questions
Can I clean the flame sensor myself?
It is possible, but only if you are comfortable opening the furnace. It is a common repair: when the thin metal rod is coated, the furnace lights and then shuts off after a few seconds. Cleaning it means switching off the power and gas and handling the burner area. If you are unsure, leave it to the technician and give them the blinking code.
Why does my furnace work after a reset and then fail again?
Because a reset clears the lockout, not the cause. A repeating fault usually means a sensor, pressure switch or vent problem that needs testing. In Monument and other snowy spots, drifted snow over side-wall vent pipes is a frequent trigger. Clear the pipes, count the blinking code and write it down. If the same code returns, stop resetting it and call a technician.
Related guides
Furnace and heating repair · What HVAC repairs cost in the Colorado Springs area · Services