Skip to content

Referral line for the Pikes Peak region · Your call goes to an independent HVAC technician

HVAC Repair ProsHeating & cooling · Pikes Peak region
Heating and cooling repairColorado Springs · Fountain · Monument
Talk to a local technician(000) 000-0000
(000) 000-0000

HVAC service · Colorado Springs area

Thermostat, ductwork and airflow repair

If one bedroom is freezing, the upstairs is too hot or the thermostat screen has gone blank, the problem is often the thermostat, its wiring, the blower or the ductwork, not the furnace itself. Call this line to reach an independent technician in Colorado Springs, Fountain or Monument.

Call (000) 000-0000

Common problems

  • Blank thermostat: dead batteries, a tripped breaker, a blown control fuse or a missing common wire on a smart thermostat.
  • System will not follow the thermostat: wrong mode, loose wires or a thermostat that has lost its schedule after a power cut.
  • Hot upstairs, cold basement: unbalanced ducts, closed registers, a blower set to low speed or leaky duct joints.
  • Weak airflow everywhere: clogged filter, dirty blower wheel, frozen coil or crushed flexible duct.
  • Whistling or banging ducts: undersized returns or a filter that is too restrictive.

Homes in the Pikes Peak region

Many Colorado Springs homes have basements and two or more storeys, so heat rises and the top floor runs warmer. Tri-level and split-level homes from the 1960s and 1970s often have long duct runs to the far rooms. Newer homes on the north and east side may have zoning dampers that can stick. Dry winter air also makes people want a humidifier; tell the technician if your furnace has one, as its pad and valve need yearly care.

Simple checks

Replace thermostat batteries, check the filter, open every supply register and make sure furniture is not blocking return grilles. If you installed a new smart thermostat and the system stopped working, photograph the old wiring and describe it on the call.

Basements in older Colorado Springs homes often have exposed ducts that were added to over the years. Joints there can come apart, sending heated air into the basement instead of the rooms upstairs. If you can see the ducts, look for disconnected sections or gaps at the joints, and mention them when you call.

Common questions

Why is my upstairs so much warmer?

Mainly because heat rises, and many ducts are not balanced for two storeys. Colorado Springs homes often have basements plus two floors, and tri-level houses from the 1960s and 1970s have long duct runs to the far rooms. Open every register, keep return grilles clear and check the filter. A technician can measure airflow, blower speed and returns, and check any zoning dampers.

Do smart thermostats need a C-wire?

Most do. The common wire powers the screen and Wi-Fi, and without one some thermostats lose power, go blank or make the system cycle on and off. If the system stopped working after you fitted a new smart thermostat, photograph the old wiring and the furnace control board terminals. Describe them on the call so the technician can check for a C-wire or adapter.

Should I close vents in unused rooms?

Usually not many of them. Closing lots of vents can raise duct pressure, make ducts whistle and reduce efficiency, and on some systems it can trip the furnace limit switch. Closing one or two is less of a concern. If a spare room is too warm or cold, ask the technician to check duct balance and blower speed before you start shutting registers.

Where this service is available

Colorado Springs · Fountain · Monument

Other repairs: Furnace and heating repair · Air conditioning repair · Heat pump and mini-split repair

Rooms too hot or too cold?

Call and describe which rooms and when.

Call (000) 000-0000